Brand: Chemotechnique Diagnostics

Allergens
Sweden

Chemotechnique Diagnostics is a renowned Swedish manufacturer of patch tests used for diagnosing contact allergies. The company was founded in 1981 and has since been at the forefront of innovation in the field of products used for diagnosing contact allergies. In its innovations the company closely cooperates with numerous associations dealing with contact dermatitis such as the European Society of Contact Dermatitis (ESCD).

Haptens by Chemotechnique Diagnostics are grouped into series the most well-known of which is the European Baseline Series including 29 haptens. In addition to it, there are other series, i.e. sets of haptens such as: bakery series, corticosteroid series, cosmetic series, dental series, hairdressing series, fragrance series, medicament series, shoe series, metal series and many others.

Proizvodni program: Sets of haptens for patch tests in diagnosing contact allergies, strips with chambers for the application of patch tests, application device for strips, plate for reading and interpreting allergic reactions, skin markers, nickel tests, cobalt tests

This board makes easier the application of haptens to IQ Ultra strips. The board prevents sliding of the foil when dispensing haptens. Furthermore, the board includes the special part for removing caps from the hapten syringe, eliminating contamination during the dispensing of haptens.

Group: Allergens

European Baseline Series is the set consisting of 29 haptens, i.e. the substances which skin most frequently gets in contact with. It is used as the starting test in diagnosing contact dermatitis. European Baseline Series by Chemotechnique Diagnostics is made upon strict recommendation of the European Society of Contact Dermatitis (ESCD). This recommendation particularly refers to the perfume mix 2 and hydroxyisohexyl 3-cyclohexen carboxaldehyde (Lyral) which are included in this series.

Group: Allergens

Each IQ Ultra strip contains 10 inert square chambers made of polyethylene foam attached to hypoallergenic strip (IQ Ultra). Polyethylene foam is inert and does not contain additives. There is no danger of chemical interaction between the hapten and the chamber. The patented design makes it easy to distinguish between allergic and irritative reaction. Major advantage of these chambers is that you can open the strip, apply the hapten content to the polyethylene foam and then paste the strip closed again and leave it the refrigerator for subsequent use.

Thus prepared strip may be stored in the refrigerator up to two weeks.

Group: Allergens

This plate is used for interpreting allergic reactions. It is designed to match the size of the IQ Ultra strip. It contains 10 transparent fields through which the skin reactions to haptens are observed.

Group: Allergens

Used for making the spot of the allergic reaction. The marker contains methyl rosaniline and silver nitrate making it more durable.

Group: Allergens